background image

WARNING

WARNING

WARNING

CAUTION

Never Do This

Always Do This

WARNING

WARNING

Precautions

Safety
Precautions

3

ENGLISH

To prevent injury and property damage, follow these instructions.

Incorrect operation due to ignoring instructions will cause harm or damage, the seriousness of which is
indicated by the following symbols.

■ 

Do not install, remove and reinstall the unit by yourself.

• Improper installation will cause water leakage, electrical shock, or fire. Please consult

authorized dealer or specialist for the installation work. Please note fault caused by improper
installation is not covered by warranty.

• Unit must be installed in an easily accessible area. Any additional cost required to hire a

special equipment to service the unit will be the responsibility of the customer.

Do not damage or use an
unspecified power cable.

• It will cause electrical shock or fire.
• If the supply cord is damaged, it

must be replaced by a service
agent or a similarly qualified
person in order to avoid a hazard.

Do not operate switches with
wet hands.

• It may cause electrical shock.

Plug in the power plug
properly.

• It will cause electrical shock

or fire due to heat
generation.

Do not operate or stop the unit by
inserting or pulling out the power plug.

• It will cause electrical shock or fire due to heat

generation.

Do not expose the skin to cool air directly for
a long time.

• This could damage your health.

If an abnormality (smell of burning, etc)
occurs, stop the air conditioner, and 
turn off the breaker.

• If the unit continues to be operated in an abnormal

condition, it may cause a fire, trouble, etc. In this
case, consult your dealer.

Repair or relocation should not be done by
the customer.

• If this is done incorrectly, it may cause a fire,

electric shock, injury by dropping of the unit, water
leakage, etc. Consult your dealer.

This symbol shows the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

Installation precautions

Содержание LT-D4880RJ

Страница 1: ...and preventing improper use PRECAUTIONS Pay close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation LG is not responsible for any damages caused by misuse of the product LG Cassette Type Air Conditioner OWNER S MANUAL LG Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides ...

Страница 2: ...ng tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play...

Страница 3: ...y cord is damaged it must be replaced by a service agent or a similarly qualified person in order to avoid a hazard Do not operate switches with wet hands It may cause electrical shock Plug in the power plug properly It will cause electrical shock or fire due to heat generation Do not operate or stop the unit by inserting or pulling out the power plug It will cause electrical shock or fire due to ...

Страница 4: ...high humidity e g leaving a door or window open In the cooling mode if it is operated in a room with high humidity 80 r h or more for a long time water condensed in the air conditioner may drop and may wet and spoil furniture etc Do not step onto an unstable bench when attaching detaching the panel It may case an injury etc by falling down Do not use for special purposes Do not use this air condit...

Страница 5: ...ls from the remote control Signal receiving sound two short beeps or one long beep Operation Indication Lamps On Off Lights up during the system operation Filter Sign Lights up after 2400 hours from the time of first operating unit Refer to page 19 Timer Lights up during Timer operation Defrost Mode Lights up during Defrost Mode or Hot Start operation Heat pump model only Outdoor Unit Lights up du...

Страница 6: ...ed to select the operation mode Auto Operation Mode Cooling Operation Mode Soft Dry Operation Mode Heating Operation Mode except cooling model Auto Swing Button Used to swing up and down Room Temperature Checking Button Used to check the room temperature Plasma Air Clean Button optional Timer Cancel Button Used to cancel the timer Timer Set Button Used to set the timer when the desired time is obt...

Страница 7: ...d to circulate the room air without cooling or heating turns indoor fan on off ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature RESET BUTTON Used prior to resetting time or after replacing batteries INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low medium high or CHAOS ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature ORERATION MODE SELECTIO...

Страница 8: ...JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP Hour Min Week RESET Set the Current Time and day of the Week 1Press the button Each time the button is pressed the number is changed from 0 0 to 2 3 This number indicates current hour For example if it is 14 25 press button 14 times...

Страница 9: ...4 OPERATION FAN SPEED SUB FUNCTION SET TEMP 01 03 05 07 09 11 13 15 17 19 21 23 Time Weekly Programming 1Press the Program button The remote controller is displayed like a picture Then and 01 is blinked 2 Press the button Press button repeatedly until desired mode appears For example if you want Thu press button 4 times 3Select the time you want Press or button then blinking letter is shown If you...

Страница 10: ...EED SUB FUNCTION SET TEMP 01 03 05 07 09 11 13 15 17 19 21 23 Time AUTO SWING 10 If Tuesday is a holiday in this week you may set a holiday Press the Program button 1 Press the Week button Select the Tuesday 2 Press the Holiday button Then the remote controller will be displayed The outside rectangular means holiday 3 Program Press the Timer button 1 Timer Min Hour Press or button then you can con...

Страница 11: ...rost Filter Preheat Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 Plasma 3 1 4 2 11 ENGLISH Operation Mode Operation Procedure Cooling Mode Cooling Mode Soft Dry Mode Auto Mode Cooling Model Soft Dry Mode Heating Mode Auto Mode Heat Pump Model 1st 2nd 3rd 4th On Off Button Operation Mode Selection Button Room Temperature Setting Button Indoor Fan Speed Selection Button...

Страница 12: ...G OPERATION FAN SPEED SUB FUNCTION SET TEMP AUTO HEAT PUMP MODEL Cooling Operation Soft Dry Operation Heating Operation Auto Operation Operation Display ZONE Operation unit Program set RoomTemp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP HI LO HI ZONE O...

Страница 13: ...Program set RoomTemp MED AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP LO ZONE Operation unit Program set RoomTemp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWIN...

Страница 14: ...15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP HI Defrost ZONE Operation unit Program set RoomTemp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP HI LO HI ZONE Operation unit Program set RoomTemp MED JET Heater Defrost Filter P...

Страница 15: ...mperature Cold Cool Proper Warm Hot Auto Operation Mode Cooling model 1Press the On Off Button 2To select Auto Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow During Auto Operation You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired ...

Страница 16: ... 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP AUTO HEAT PUMP MODEL Cooling Operation Soft Dry Operation Heating Operation Auto Operation Operation Display HI ZONE Operation unit Program set Room Temp MED LO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN...

Страница 17: ...ion unit Program set Room Temp MED AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP LO HI ZONE Operation unit Program set Room Temp LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4...

Страница 18: ...peed on cooling mode 3To cancel the Jet Cool mode press the Jet Cool button again or the Fan Speed button or the room Set Temperature button and the unit will operate in high fan speed on cooling mode NOTE During the Jet Cool function at any moment the A C starts to blow the cool air at extremely high speed setting the room temp automatically to 18 C It is especially used to cool the room temp in ...

Страница 19: ...rocedure To set the Child Lock Function Press the Timer button and Minute Set button for three seconds Then the operation mode shift to child lock mode and it is displayed CL in the operation display When you press any button in this time the remote controller is not converted to any selected mode and the CL is displayed in the remote controller for about three seconds But the Room Temperature fun...

Страница 20: ...tarting Operation is the function to operate procedures automatically to the previous operating conditions Filter sign lamp LED is ON If LED indicating filter sign lamp is ON clean the filter After cleaning the filter press the Timer button and button of wired remote controller at the same time for 3 sec Then filter sign LED is OFF Heat pump Model Cooling Model Room Temp set Temp 2 C Room Temp set...

Страница 21: ...ry cloth Do not use bleach or abrasives NOTE Supply power must be disconnected before cleaning the indoor unit When the air filter is to be removed do not touch the metal parts of the indoor unit It may cause an injury Remove the Air filters Take hold of the tab and pull slightly forward to remove the filter Clean dirt from the air filter using a vacuum cleaner or washing with water If dirt is con...

Страница 22: ...he air filters pull slightly forward to remove the PLASMA filter Dip the PLASMA filter into the water mixed with neutral detergent for 20 30 minutes Dry the PLASMA filter in the shade for a day Especially the humidity must be removed perfectly on this parts Note the cuts of electric discharge lines Re install the PLASMA filter to the original position Don t touch this PLASMA Filter within 10 secon...

Страница 23: ... ground wire is connected correctly It may be connect to the indoor unit side Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the ro...

Страница 24: ... conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the setting temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obs...

Страница 25: ...P No 3828A20111P Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...

Отзывы: