1. Heavy Repair SVC Method
For the heaver repair of R134a type of refrigerator, perform work according to following SVC method.
1-1. Return of Refrigerator Refrigerant
Required equipment: Pinch pliers, refrigerant discharging hose, refrigerant returnbag
• Take power cords out and remove power between 6sec through 12sec after powering ON to open all both sides of 3way
valve.
• Leave doors of a refrigerator so that they are not closed.
• Connect pinch pliers with a refrigerant discharging hose.
• Place the outlet of a refrigerant discharging hose outside.
(Remove fire appliances or heating sources near a refrigerant discharging hose.)
• Always use a refrigerant returnbag for working at the contained space.
• Bore the charging pipe of a compressor with pinch pliers.
(Remove fire appliances or heating sources near a refrigerator.)
• Perform refrigerant discharge for more than 7 minutes.
Suction Pipe
Discharge Pipe
Pinch Plier
Process Pipe
Refrigerant ReturnBag
Heavy Repair Method of Refrigerator by Application of Refrigerant
Heavy Repair Method of Refrigerator by Application of Refrigerant
Содержание LSXS26326
Страница 9: ...Circuit Diagram ...
Страница 25: ...Micom Circuit description ...
Страница 31: ...Compressor ...
Страница 33: ...Compressor ...
Страница 34: ...Compressor ...
Страница 35: ...Compressor ...
Страница 50: ...Troubleshooting ...
Страница 52: ...Troubleshooting ...
Страница 54: ...Troubleshooting ...
Страница 55: ...Troubleshooting 2 9 Communication Error CO E ...
Страница 74: ...REFRIGERATOR DOOR EV 241B 241A 212G 231B 231A 230A 244F 241D 241H 241F 271D 233A 212K 212K 212J ...
Страница 78: ...August 2014 MFL ...