Troubleshooting
33
0
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-1)
ResultSVC Action
No
1
2
Checking flow
Check for a loose connection.
Check the Pin10(1) to Pin11(2)
of CON8.
Result & SVC Action
CON8
<Temperature table-1>
(1) To (2)
-22°F / -30°C
-13°F / -25°C
-4°F / -20°C
5°F / -15°C
14°F / -10°C
23°F / -5°C
32°F / 0°C
Result
40
30
23
17
13
10
8
The sensor is determined by
the temperature.
For example, 23
indicates -20°C
2. Troubleshooting With Error Display
1) Freezer Sensor Error(FS E)