17
Micom Function
2-11. Test Function
TEST KEY EXISTS ON PWB ASSY. MAIN BOARD.
MODE
OPERATION
CONTENTS
REMARKS
PRESS TEST
BUTTON ONCE
<Strong Cold mode>
1. CONTINUOUS OPERATION OF COMPRESSOR
AND CONDENSER FAN MOTOR.
2. ALL DEFROST HEATERS TURNS OFF
3. 10 MINUTES IN EARLY STAGE REFRIGERATOR
FAN MOTOR ON
4. AFTER 10 MINUTES ALL FAN MOTORS ON WHEN
THE FREEZER SENSOR IS ABOVE 41°F AND
REFRIGERATOR SENSOR IS ABOVE 59°F
5. JUST REFRIGERATOR FAN MOTOR
ON WHEN THE FREEZER SENSOR
IS BELOW 10°F AND
REFRIGERATOR SENSOR IS ABOVE
35°F
6. REMAINING CONDITION FREEZER
FAN MOTOR ON
FREEZER FAN MOTOR TURNS OFF
IN FREEZER ROOM DOOR OPENING.
REFRIGERATOR FAN MOTOR TURNS
OFF IN REFRIGERATOR ROOM DOOR
OPENING.
RETURNS TO THE NORMAL MODE
WHEN THE FREEZER DEFROST
SENSOR IS ABOVE 41°F AND
REFRIGERATOR DEFROST SENSOR
IS ABOVE 64°F
TEST1
PRESS TEST
BUTTON ONCE AT
THE TEST MODE 1
STATUS <Forced
Defrost mode>
PRESS TEST
BUTTON ONCE AT
THE TEST MODE 2
STATUS
1. COMPRESSOR OFF
2. ALL FAN MOTORS OFF
3. ALL DEFROST HEATERS ON
RETURNING TO INITIAL STATUS
COMPERSSOR WILL OPERATE
AFTER DELAY FOR 3 MINUTES
4. ALL DISPLAY GRAPHICS TURNS
OFF (ONLY FAILURE CODE
INDICATION PART TURNS ON “22
22” STATUS)
TEST2
NORMAL
STATUS