7-14
TEST AND CHECKOUT PRECEDURES AND TROUBLESHOOTING
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE OUTER CASE
FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH VOLTAGE CAPACITOR
AND REMOVING THE LEAD WIRES FROM THE PRIMARY WINDING OF THE HIGH VOLTAGE TRANSFORMER.
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER OF
WATER IN CONTAINER)IN THE OVEN.
A. TEST PROCEDURES
TRANSFORMER
MAGNETRON
1. Remove wire leads.
2. Measure resistance. (ohm meter scale: Rx1)
• Primary winding
• Secondary winding
• Filament winding
3. Measure resistance. (ohm meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Remove wire leads. Install the magnetron seal
in the correct position. Check that the seal is in
good condition.
2. Measure resistance. (ohm meter scale: Rx1)
• Filament terminal
3. Measure resistance. (ohm meter scale: Rx1000)
• Filament to chassis
Normal: Less than 1 ohm
Normal: Infinite
COMPONENTS
TEST
RESULTS
SECONDARY
WINDING
PRIMARY
WINDING
FILAMENT
WINDING
Approx. 0.3 to 0.5 ohms
Approx. 65 to 120 ohms
0 ohm
Normal: Infinite
Normal: Infinite
Antenna
Gasket
Chassis
Содержание LSMC3086ST
Страница 7: ...4 1 OPERATING INSTRUCTIONS CONTROL PANEL 1 2 4 6 3 9 12 14 15 18 21 7 10 13 16 19 17 20 11 8 5 ...
Страница 37: ...2004 2381 2028 2011 2008 260M 2030 2006 2400 2041 2043 2042 EV CONTROLLER PARTS ...
Страница 38: ...OVEN CAVITY PARTS 3103 3031 3001 3029 3024 3010 6001 3005 W178 W202 3026 3011 3025 3032 3009 3045 3037 6000 EV ...
Страница 39: ...LATCH BOARD PARTS 4001 4000 4002 W102 4003 4002 4004 EV ...
Страница 42: ...INSTALLATION PARTS VINYL BAG 6009 6008 6011 6010 EV ...
Страница 43: ......