background image

ENGLISH

Owner's Manual 23

Maintenance and Service

Cleaning of Purifying Filter

• Recomended use period : About 3 months

Slide down the bottom panel.

Bend and pull off the 4th panel.
(Rib of the panel off the hole.)

2

1

Remove the Air Filter.

Relocate dried Air Filter.

4

3

Put in the 4th panel then slide up the bottom
panel.

5

Содержание LSC091PMA

Страница 1: ... Conditioner LG Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly IMPORTANT OWNER S MANUAL ...

Страница 2: ... of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ...

Страница 3: ...own below Be sure not to do Be sure to follow the instruction Installation Always perform grounding Otherwise it may cause electrical shock Don t use a power cord a plug or a loose socket which is damaged Otherwise it may cause a fire or electrical shock For installation of the product always contact the service center or a professional installation agency Otherwise it may cause a fire electrical ...

Страница 4: ...place that ther is concern of falling down Otherwise it may result in personal injury Use caution when unpacking and installing Sharp edges may cause injury Do not share the outlet with other appliances It will cause an electric shock or a fire due to heat generation Do not use the damaged power cord Otherwise it may cause a fire or electrical shock Do not modify or extend the power cord randomly ...

Страница 5: ...e head when taking it out It may cause electric shock and damage Never touch the metal parts of the unit when removing the filter They are sharp and may cause injury Ventilate the room well when using this appliance together with a stove etc An oxygen shortage may occur When cleaning the unit first make sure the power and breaker are turned off Otherwise it may cause electrical shock Turn off the ...

Страница 6: ...Install the drain hose to ensure that drain can be securely done Otherwise it may cause water leakage Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors Otherwise it may cause dispute with the neighbors Always inspect gas leakage after the installation and repair of product Otherwise it may cause the failure of product Keep level paral...

Страница 7: ...gent The appearance of the air conditioner may deteriorate change color or develop surface flaws When gas leaks open the window for ventilation before operating the unit Otherwise it may cause explosion and a fire Do not use an appliance for special purposes such as preserving animals vegetables precision machine or art articles Otherwise it may damage your properties Do not place obstacles around...

Страница 8: ...ce together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purpose e g preserving precision devices food pets plants or art objects Such use may damage your properties 1 Do not touch the metal parts of the unit when removing the filter Injury can occur 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulati...

Страница 9: ...m the power plug WARNING Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring WARNING If you have any doubt whether the air conditioner is properly grounded have the wall receptacle and circuit checked by a qualified electrician Preferred ...

Страница 10: ...the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage WARNING Never use the appliance with a broken adapter We strongly discourage the use of an extension cord due to potential safety hazards For temporary situations use only CSA certified and UL listed 3 wire grounde...

Страница 11: ...he remote controller may be stored by mounting it on a wall To operate the room air conditioner aim the remote controller at the signal receptor Signal Receptor Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Operation Indication Lamps On Off Lights up during the system operation Sleep Mode Lights up during Sleep Mode Auto operation Timer Lights...

Страница 12: ...or stop the speed cooling heaing speed cooling heating operates super high fan speed in cooling heatig mode 6 CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction 7 ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation See page 19 8 TIME SETTING BUTTONS Used to adjust the time See page 19 9 TIMER SET CANCEL BUTTON Used to set...

Страница 13: ...ose the door of the remote controller Set the temperature lower than the room temperature The temperature can be set within a range of 64 F 86 F 18 C 30 C at intervals of 2 F 1 C Set the fan speed again with the door of the remote controller still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted 1 2 3 4 Natura...

Страница 14: ...ure Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will be changed automatically During Auto Operation You cannot control the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired manually switch to another mode The system will not automatically switch from the cooling mode ...

Страница 15: ...an Speed Selector and set to CHAOS mode In this mode the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic Healthy dehumidification operation During Healthy Dehumidification Operation If you select the dehumidification mode on the operation selection button the A C starts to run the dehumidification function It automatically sets the room temp and ai...

Страница 16: ...e direction of the arrow Close the door of the remote controller Set the temperature higher than the room temperature The temperature can be set within a range of 60 F 86 F 16 C 30 C at intervals of 2 F 1 C Set the fan speed again with the door of the remote controller still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mo...

Страница 17: ... the Jet Cool Heat mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL HEAT button again NOTICE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate at super high fan speed on cooling mode for 30 minutes To cancel the Jet Cool mod...

Страница 18: ...control and press the 2nd Function button to operate functions printed in blue unter buttons Check the indication of 2nd function on the display of the remote controller These buttons can set the timer as follows 2nd function disappears in a short time automatically or when the button is pressed again 1 2 3 2nd F operation For more details refer to functions next pages ...

Страница 19: ...n 1 hour for a comfortable sleep NOTICE Setting the time 1 Time can be set only when you press the Reset button Having replacing the batteries you should press the reset buttons to reset the time Press the Start Stop button 2 Press 2nd F button and check if 2nd F icon is on 3 Press the Time Setting buttons until the desired time is set 4 Press the Timer SET button Check the indicator for A M and P...

Страница 20: ...rs return to the maximum airflow position automatically Air circulation mode Circulates the room air without cooling or heating 1 Press the Start Stop button the unit will respond with a beep 2 Open the door on the remote control Press the Air Circulation button Close the door on the remote control Now each time that you press the Indoor Fan Speed Selector the fan speed is shifted from low to CHAO...

Страница 21: ...ity The cooling capacity indicated in the specification is the value when the fan speed is set to high and the capacity will be lower at low or medium fan speed High fan speed is recommended when you wish to cool the room quickly Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation...

Страница 22: ...ke the filter out slowly Clean the filter after stopping the product 2 Clean the filter with a vacuum or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 104 F 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter Never use any of the followings Water hotter than 104 F 40 C Could ...

Страница 23: ...g of Purifying Filter Recomended use period About 3 months Slide down the bottom panel Bend and pull off the 4th panel Rib of the panel off the hole 2 1 Remove the Air Filter Relocate dried Air Filter 4 3 Put in the 4th panel then slide up the bottom panel 5 ...

Страница 24: ...structed and that there is a clearance of over 20 between the back of the air conditioner and the wall or fence behind it 4 Close all doors and windows and check for any source of heat in the room Before calling for service please review the following list of common problems and solutions The air conditioner is operating normally when You hear a pinging noise This is caused by water being picked u...

Страница 25: ...etely into the outlet Check the house fuse circuit breaker box and replace the fuse or reset the breaker If power failure occurs turn the mode control to Off When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Turn the knob to a higher number...

Страница 26: ...26 Room Air Conditioner Memo ...

Отзывы: