GENERAL INSTALLATION GUIDELINES
Required Clearances
Figure 4: Outdoor Unit Clearances
Outdoor Unit Clearance
12
28
24
12
24
Unit : inch
Do not place the unit where animals and/or plants will be in the path of the warm air, or where the warm air and/or noise will disturb neighbors.
Figure 5: Outdoor Unit Sunroof/Awning Clearances
More than
12
More than
12
Sunroof
Fence or
obstacle
s
More than
28
Unit : inch
More than
24
9/12k Indoor Units:
≥
5
18k Indoor Units:
≥
8
More than 4
More than 4
At least 6.5 from the floor
Unit: Inch
Indoor Unit Clearance
Follow recommended best practices when choosing an indoor loca-
tion for the Single Zone indoor unit.
• Keep unit away from any indoor steam or excessive heat.
• No obstacles should be placed around unit.
• Condensation drain (Leakage piping) should be routed away from
the unit.
• Do not install near doorway.
• Clearance gap between any wall or enclosure and the left or right
side of the unit must be greater than 4 inches.
• From the top of the unit to the ceiling there must be greater than 5
or 8 inches of clearance (depending on indoor unit model).
•
Unit should be at least 6.5 feet from the floor for adequate clearance.
Figure 6: Clearances Where There Are Obstacles on Both Air
Inlet and Outlet Sides (Obstacle on the Outlet Side is Lower
Than the Outdoor Unit)
Figure 7: Clearances Where There are Obstacles Above and on Both Air Inlet
and Outlet Sides (Obstacle on the Outlet Side is Lower Than the Outdoor Unit)
Figure 8: Indoor Unit Clearance Recommendations
Minimum
28
Minimum
12
Unit: Inch
Minimum
12
79
24
Minimum 28
Unit: Inch