Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
PERFORMANCE DATA | 67
Performance Data
Maximum Heating Capacity
PERFORMANCE DATA
Maximum Heating Capacity Table for LS090HEV2 (LSU0
LSN090HEV2)
Maximum Heating Capacity Table for LS120HEV2 (LSU1
LSN120HEV2)
Table 36: LSN090HEV2 / LSU090HEV2 Heating Capacities.
Outdoor Air
Temp.
Indoor Air Temperature (°F DB)
°F DB °F WB
60
64
68
70
72
75
86
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
16
14
8.37
1.15
8.25
1.17
8.13
1.18
8.08
1.19
7.84
1.17
7.51
1.15
6.22
1.06
17
15
8.68
1.16
8.56
1.18
8.44
1.19
8.39
1.20
8.14
1.18
7.80
1.14
6.44
1.01
19
17
9.17
1.16
9.05
1.18
8.92
1.19
8.76
1.20
8.58
1.17
8.19
1.13
6.68
0.99
24
23
10.07
1.17
9.93
1.18
9.80
1.18
9.74
1.18
9.36
1.15
8.83
1.11
6.89
0.95
32
30
10.97
1.13
10.84
1.14
10.70
1.14
10.64
1.14
10.13
1.10
9.43
1.05
6.95
0.86
41
38
11.84
1.05
11.70
1.07
11.55
1.10
11.49
1.11
10.90
1.05
10.09
0.99
7.33
0.73
43
40
12.20
1.01
12.05
1.03
11.91
1.05
11.84
1.06
11.22
1.01
10.37
0.93
7.47
0.67
47
43
12.93
0.97
12.78
1.00
12.63
1.04
12.52
1.05
11.90
0.99
10.99
0.91
7.90
0.63
53
50
12.74
0.94
12.58
0.97
12.42
1.01
12.45
1.02
11.61
0.96
10.61
0.86
7.29
0.53
59
53
12.59
0.92
12.58
0.96
12.57
1.00
12.46
1.02
11.77
0.95
10.68
0.86
7.19
0.54
64
57
12.81
0.90
12.62
0.91
12.42
0.93
12.33
0.94
11.57
0.88
10.53
0.80
7.11
0.52
70
61
12.86
0.85
12.63
0.85
12.40
0.85
12.30
0.85
11.55
0.80
10.52
0.73
7.14
0.47
75
65
13.05
0.77
12.78
0.79
12.51
0.82
12.28
0.83
11.62
0.78
10.58
0.70
7.08
0.43
Table 37: LSN120HEV2 / LSU120HEV2 Heating Capacities.
Outdoor Air
Temp.
Indoor Air Temperature (°F DB)
°F DB °F WB
60
64
68
70
72
75
86
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
16
14
9.21
1.31
9.08
1.33
8.95
1.35
8.89
1.36
8.63
1.34
8.27
1.31
6.85
1.21
17
15
9.56
1.33
9.43
1.35
9.29
1.36
9.23
1.37
8.96
1.34
8.59
1.30
7.09
1.15
19
17
10.10
1.33
9.96
1.35
9.82
1.36
9.64
1.37
9.45
1.34
9.02
1.29
7.35
1.14
24
23
11.08
1.34
10.94
1.34
10.79
1.35
10.73
1.35
10.30
1.31
9.72
1.27
7.58
1.09
32
30
12.08
1.30
11.93
1.30
11.78
1.30
11.71
1.30
11.15
1.26
10.38
1.20
7.65
0.99
41
38
13.03
1.20
12.88
1.23
12.72
1.25
12.65
1.26
12.00
1.21
11.11
1.13
8.07
0.84
43
40
13.43
1.15
13.27
1.17
13.11
1.20
13.04
1.21
12.35
1.15
11.41
1.07
8.22
0.77
47
43
14.23
1.11
14.07
1.14
13.91
1.18
13.78
1.20
13.10
1.14
12.10
1.05
8.70
0.72
53
50
14.03
1.08
13.85
1.11
13.67
1.15
13.71
1.17
12.79
1.09
11.69
0.99
8.02
0.61
59
53
13.86
1.05
13.85
1.10
13.84
1.14
13.71
1.16
12.96
1.09
11.76
0.99
7.91
0.61
64
57
14.11
1.03
13.89
1.04
13.67
1.06
13.58
1.07
12.74
1.01
11.60
0.92
7.83
0.59
70
61
14.16
0.98
13.91
0.97
13.65
0.97
13.54
0.97
12.71
0.91
11.58
0.83
7.87
0.54
75
65
14.36
0.88
14.07
0.91
13.77
0.94
13.52
0.95
12.79
0.89
11.64
0.80
7.80
0.49
DB: Dry Bulb Temperature (°F) WB: Wet Bulb Temperature (°F) TC: Total Capacity (kBtu/h)
PI: Power Input (kW) (includes compressor, indoor fan motor and outdoor fan motor)
1. All capacities are net, evaporator fan motor heat is deducted.
2. Direct interpolation is permissible. Do not extrapolate.
Capacity as rated: 0 ft. above sea level with 24.6 ft. of refrigerant piping. 0 ft. level difference between
outdoor and indoor units.
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB), and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).