ELECTRICAL WIRING
Figure 90: Indoor Unit Knockout (Communication Wires)
Figure 91: Indoor Unit Terminal Block with Grounding Cable
(Example Only)
Indoor Unit Electrical Connections
Connecting Indoor Unit Electrical Wiring - Continued
5. When done, reattach the bottom panel to the indoor unit, being careful to align panel using the rear tabs.
• You might need to give the panel a gentle tap with the palm of your hand to be sure it engages at the bottom.
6. Using a phillips screwdriver, reattach the screws to the bottom panel and secure.
7. Once screws are in place, re-snap the latches over the screws.
• Refer back to Figure 87 as an example.
8. If all other piping and electrical wiring to the outside unit has been completed at this stage, you can turn the system on to test.
• If you have not completed the piping connections,
do not turn power on at this time and proceed to complete all other piping, (along
with drain hose) and wiring to the system.
Terminal Block Connection for HLV
See Figure 92 for specific terminal block wiring for all following
Single Zone models:
LSN240HLV
LSN300HLV
LSN360HLV
Control Cover
Bottom Panel
Electrical Wiring
Knockout
Indoor Unit
1(L1) 2(L2)
3
1(L ) 2 (N )
3
Power Connection Cable
Grounding Cable
Figure 92: HLV Indoor Units - Terminal Block Connections