Installation
1) Selection of the best location
1. Indoor unit.
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles to prevent the air
circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consid-
eration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
2. Outdoor unit.
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat radia-
tion from the condenser is not restricted.
• There should not be any animals or plants which
could affected by hot air discharged.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
3. Piping length and the elevation.
Ringt
Rear right
Down right
Rear left
left
Front
Pipe size
Max. piping
Max.
GAS LIQUID
A(m)
B(m)
3/8"
1/4"
7
5
1/2"
1/4"
7
5
More than
5cm
More than 5cm
More than eye-level
More than
5cm
More than
70cm
More than
10cm
More than
10cm
A
B
Indoor unit
Outdoor unit
1. Installation of indoor, Outdoor unit
ƒ¡
22
ƒ¡
LS-P0760CL/P0760HL
LS-P0820CL
LS-P0960CL/P0960HL
LS-S0960CL/S0960HL
LS-S1120CL
LS-S1260CL/S1260HL
LS-S1420CL/S1421CL
length
elevation