5. Auto Operation
ƒU
The operation procedure is as following.
ƒN
If initial mode is decided, that mode is continued without the room temperature changing.
ƒ
ƒU
U
Auto Operation for Cooling.
ƒ¡
15
ƒ¡
Press Start/Stop Button
Select Auto Operation Mode
Check the Room temperature
Operation mode
Indoor fan speed
are automatically decided by Fuzzy rule.
Setting temperature
Intake-air
temperature
Operation Mode
Heating
Soft Dry
Cooling
Operation Condition
Intake-air Temperature
Setting temperature
Fan speed
Air Direction Control
Over 26°C
25°C
Over 24°C~below 26°C
Intake air -1.0°C
Over 22°C~below 24°C
Intake air -0.5°C
Over 20°C~below 22°C Intake air temperature
below 20°C
20°C
Over 20°C~below 30°C
Fuzzy control
below 20°C
20°C
Over 30°C
30°C
below 21
¡
below
24
¡
~
Over 24
¡
Over
21
¡
When Auto Operation
initial start
When Switch to
Auto Operation
Controlled
by Fuzzy logic
1/f rhythm
Intake-Air temp
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp.-0.5°C
(Compressor ON)
Indoor Fan
Compressor
ON
OFF
ON
OFF
Fuzzy Speed
¢”
¢”
Содержание LS-0960CL