![LG LRSES2706V /01 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/lg/lrses2706v-01/lrses2706v-01_service-manual_1902092063.webp)
6. Poor/Over cooling in Fresh food section
1. Poor cooling in Fresh
food section
Symptom
Check Point
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4. Check the R-Damper motor voltage
CON6
R1SNR
Resistance
[Ω]
23ºF /-5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Duct
Status
Air Flow
Windy
Air Temperature
Cold
Duct
Fan Motor
CON7
CON8
TEST MODE 1
Voltage
[V]
CON8 9
th
pin ~ 12
th
pin
10~12 VDC
CON8 9
th
pin ~ 19
th
pin
2~4.5 VDC
CON8 9
th
pin ~ 10
th
pin
Not 0V, 5V
19
th
pin~20
th
pin
CON7
CON8
63
Copyright © 2020 LG Electronics Inc. All rights
reserved. Only training and service purposes.
Содержание LRSES2706V /01
Страница 10: ...Circuit Diagram 10 Copyright 2020 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 28: ...Compressor 28 Copyright 2020 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 29: ...Compressor 29 Copyright 2020 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 30: ...Compressor 30 Copyright 2020 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 31: ...Compressor 31 Copyright 2020 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 32: ...Compressor 32 Copyright 2020 LG Electronics Inc All rights reserved Only training and service purposes ...
Страница 83: ...210A 210C 203A 201A EV EXPLODED VIEW FREEZER DOOR 619F ...
Страница 88: ...Sep 2020 MFL71760658 ...