2. Control Method
2-1. Start Position
1. After POWER OFF or Power Outage, check the EJECTOR's position with MICOM initialization to restart.
2. How to check if it is in place:
- Check
HIGH/LOW
signals from HALL SENSOR in MICOM PIN.
3. Control Method to check if it is in place:
(1) EJECTOR is in place,
- It is an initialized control, so the mode can be changed to ice making control.
(2) EJECTOR isn't in place:
A. If EJECTOR is back in place within 2 minutes with the motor on, it is being initialized. If not, go to Step B.
B. If EJECTOR is back in place within 18 minutes with the heater on (to control Heater on its OFF condition), it is being
initialized. If not, it is not functioning. Repeat Step B with Heater and Motor off.
2-2. Icemaking Mode
1. Icemaking control refers to the freezing of supplied water in the ice trays. Complete Icemaking operations by measuring
the temperature of the Tray with Icemaking SENSOR.
2. Icemaking starts after completing fulfilled ice control and initial control.
3. The Icemaking function is completed when the sensor reaches 19°F(-7°C), 60 to 240 minutes after starting.
4. If the temperature sensor is defective, the Icemaking function will be completed in 4 hours.
2-3. Harvest with Dump Mode
1. Harvest with Dump control refers to the operation of dropping cubes into the ice bin from the tray when Icemaking has
completed.
2. Harvest with Dump control mode:
(1) Operates Heater for 30 seconds; then operate MOTOR.
(2) After performing Step 1 (to control the Heater on its off condition), Ice-Removal control will be back in place wthin 18
minutes. (Hall SENSOR sign = OV). Ice removal is then complete. Then change the mode to the water supply control.
If this control phase fails to start, it is not functioning. Put the Heater and Motor in the off position. Restart every 2
hours. (Refer to fig.1)
NOTE :
If the motor malfunctions and starts before the detect lever rises, MICOM regards the Ice-Removing phase as
completed. Water then starts flowing. To prevent this, MICOM doesn’t switch to water-supply mode, but restarts the ice-
removing mode. If this happens 3 times, the motor is malfunctioning and you should stop the loads (Heater, Motor). Then
restart the Ice-Removing mode every 2 hours. (See Step 2 above.)
OPERATION PRINCIPLE AND REPAIR METHOD OF ICEMAKER
- 57 -
Heater
on
off
on
0V
5V
off
30 sec.
10 sec.
Motor
Hall IC
Ice removing
completion point
2 ms
Icemaking sensor temperature is 50
°
F(10˚C)
or more
Max. 18 minutes
After detect LEVER rises
Содержание LRSC26910SW
Страница 47: ...2 PWB parts diagram and list 2 1 PWB Assembly main part diagram LRSC269 EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 48: ...2 2 Parts list LRSC269 EXPLANATION FOR MICOM CIRCUIT 48 ...
Страница 49: ...EXPLANATION FOR MICOM CIRCUIT 49 ...
Страница 50: ...2 3 LRSC26944 LRSC26980TT DISPLAY ASSEMBLY part diagram EXPLANATION FOR MICOM CIRCUIT 50 ...
Страница 51: ...DISPLAY circuit diagram EXPLANATION FOR MICOM CIRCUIT 51 ...
Страница 53: ...DISPLAY circuit diagram EXPLANATION FOR MICOM CIRCUIT 53 PWB ASSEMBLY DISPLAY ...
Страница 54: ...3 PWB Circuit Diagram may vary according to model LRSC269 EXPLANATION FOR MICOM CIRCUIT 54 REF REF ...
Страница 60: ...CIRCUIT 60 LRSC26944 LRSC26980TT ...
Страница 102: ...TROUBLE DIAGNOSIS 102 ...
Страница 111: ...6 BLOCK DIAGRAM TV RADIO 111 ...
Страница 123: ...FREEZER DOOR PART LRSC26910 LRSC26911 EXPLODED VIEWS 123 202A 200A 210A 203A 201A 210C 210C 210C 205C 205A 205E ...
Страница 131: ...P No 3828JD8646A FEB 2004 Printed in Korea ...