8-8
TROUBLESHOOTING
3
Yes
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode,
follow these steps:
(1) press the CLEAR button
(2) press the BAKE and BROIL buttons
at the same time.
(3) press the BAKE and
BROIL buttons at the same time again.
(4) press the NUM 3 button
Normal : Themistor value at room temp is from
70˚F to 90
˚
F
Yes
Go to No 6
4
No
Range Of the resistance
Plug in the unit
Is the resistance of
thermistor normal?
Check:
Pins 4 and 5 of CN60 in main PCB
Normal- approximately 1.09kΩ at 25˚C
No
Replace the
defected
Themistor
5
Yes
Unplug the unit
CN60
6
Replace the Main PCB
igniter
Resistance[
Ω
]
Approximately
Norton Igniter
45~400
SIC Igniter
50~500
Current Oven Temp