10-14
CHECKING FLOW CHART BY FAILURE
Main oven sensing error
M
F-1, F-2 error
Check the looseness of oven sensor connector
END
No
Yes
Reconnect
Disconnect the main oven sensor and
check the main oven sensor value
(measure the resistance after cooling down)
Normal:approximately 1.06 kΩ at 65F
~ 1.12 kΩ at 85F.
NO
COM
Normal?
END
No
Yes
Replace the main oven sensor
Normal?
Main oven sensing failed
Disconnect the power