1) Remove grates, burner caps and burner
heads.
2) Remove the brass orifice spud in the chimney
of each burner using a 13/32” or 10 mm nut
driver.
3) Install the LP orifice spuds into their correct
positions as described previously.
BURNER OUTPUT RATINGS; BTU/HR
LP (Propane) Gas, 10” W.C.P
BTU RATE
ORIFICE CODE
LRG3194ST
LF
9,500
L
LR
9,100
M
RR
5,000
P
RF
10,000
Q
CTR
9,100
M
BROIL
14,500
O
BAKE
18,000
D
Orifice Locations for LP Gas
5-2
CONVERSION TO LP GAS
BURNER
MODEL
M
R
L
P
Q
LR
LF
RR
RF
CTR
WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
•
RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
4. CONVERTING THE SURFACE BURNERS
Remove the conversion kit
(see illustration below).
LP orifice spuds have a orifice code on the top or
the side, denoting the location on the range
where it is to be installed.
Denotes
orifice
code
Top burner orifices
Broil and Bake
burner orifices
M
R
L
P
Q
LR
LF
RR
RF
CTR
Denotes orifice code
Top burner orifices
Broil and Bake
burner orifices
Conversion kit
Screw