![LG LRE30453SB Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/lg/lre30453sb/lre30453sb_service-manual_218299035.webp)
4-5
Single surface units:
Right Front (RF),
Left Rear (LR)
and
Right Rear(RR)
Element
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal and 1A.
The meter should indicate 46
Ω
± 10%
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A. The meter should indicate
continuity.(0
Ω
)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below 150˚F, the meter
should indicate an open circuit(infinite).
With the temperature above 150˚F, the meter
should indicate continuity (0
Ω
).
Components