Owner’s Manual
17
ENGLISH
Control Locations
• TEMPERATURE LIMITING
Temperature Limiting can save money by limiting the lowest temperature for cooling and the highest
temperature for heating. The temperature limiting is controlled by dip switch #1 - #3.
This temperature limiting is not available with the Remote Wall Thermostat.
OFF
OFF
OFF
54°F (12.2°C) 86°F (30.0°C) 54°F (12.2°C)
86°F (30.0°C)
ON
OFF
OFF
56°F (13.3°C) 86°F (30.0°C) 54°F (12.2°C)
84°F (28.9°C)
OFF
ON
OFF
58°F (14.4°C) 86°F (30.0°C) 54°F (12.2°C)
82°F (27.8°C)
ON
ON
OFF
60°F (15.5°C) 86°F (30.0°C) 54°F (12.2°C)
80°F (26.7°C)
OFF
OFF
ON
62°F (16.6°C) 86°F (30.0°C) 54°F (12.2°C)
78°F (25.5°C)
ON
OFF
ON
64°F (17.7°C) 86°F (30.0°C) 54°F (12.2°C)
76°F (24.4°C)
OFF
ON
ON
66°F (18.9°C) 86°F (30.0°C) 54°F (12.2°C)
74°F (23.3°C)
ON
ON
ON
68°F (20.0°C) 86°F (30.0°C) 54°F (12.2°C)
72°F (22.2°C)
Temperature Temperature Temperature
Limit #1
Limit #2
Limit #3
Lowest Temp. Highest Temp. Lowest Temp. Highest Temp.
Cooling Operation
Heating Operation
• REMOVING THE FRONT GRILLE
Additional controls are available after removing the
front grille and option cover of control box.
To remove the front grille, pull out the bottom of front
grille and then lift up.
To replace the front grille, place the tabs over the top
of the unit and push the bottom of front grille until the
clips snap into place.
• ADDITIONAL CONTROLS
The additional controls are located behind the option cover of control box. The standard settings will be in
the OFF position. The authorized service man has to check switches and ensure the switches are in the
desired position.
LOCAL
1
OFF
2
OFF
3
OFF
4
OFF
5
LOCAL
1
OFF
2
OFF
3
OFF
4
OFF
5
ON
ON
REMOTE
OFF
ON
ON
ON
Remote/Local
Energy Saver
Temperature Limit#1
Temperature Limit#2
Temperature Limit#3
LOCAL
1
OFF
2
OFF
3
OFF
4
OFF
5
LOCAL
1
OFF
2
OFF
3
OFF
4
OFF
5
LOCAL
1
OFF
2
OFF
3
OFF
4
OFF
5
LOCAL
1
OFF
2
OFF
3
OFF
4
OFF
5