![LG LMXS28626 Series Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/lg/lmxs28626-series/lmxs28626-series_service-manual_1903407058.webp)
Symptom
Check Point
1. Poor cooling in
Freezer compartment
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4.Check the Fan motor sticky
5. Check the Fan motor voltage
8-17. Poor cooling in Freezer compartment
Duct
Fan Motor
CON7 17
th
pin ~ 20
th
pin
Resistance [
Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
TEST MODE 1
Voltage [V]
CON7 12
th
pin ~ 14
th
pin
12V
CON7 16
th
pin ~ 14
th
pin
0V<Voltage<5V
CON7 10
th
pin ~ 14
th
pin
0V<Voltage<5V
CON6
CON1
CON201
CON5
CON7
CON2 CON3
F-Sensor
F-Fan motor
Duct
Status
Air Flow
Windy
Air Temperature
Cold