Change the
PCB
Crush mode doesn't work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
No
Yes
6
Explain to customer
1
Check the loose connection
LEVER S/W
Voltage [V]
CON2
3
rd
pin ~ 4
th
pin
Pushing
112~115V
Not
Pushing
0~2V
3
Check the voltage.
(while pushing the lever S/W)
Is voltage correct compared with
table?
No
Yes
LEVER S/W
Voltage [V]
CON3 5
th
pin ~
CON1 13
th
pin
Pushing
9~12V
Not
Pushing
0~2V
Change the
PCB
4
Check the resistance value.
Is Geared Motor resistance
87 ~ 107
Ω
?
No
Yes
Replace
Geared Motor
Resistance
[
Ω]
Geared Motor
31.1 ~ 42.1
5
Check the resistance value.
Is Dispenser Motor resistance
9.9 ~ 12.1
Ω
?
No
Yes
Replace
Geared Motor
Resistance
[
Ω]
Dispenser Motor
9.9 ~ 12.1
(SB)
(WH)
CON2
CON3 CON1
Geared Motor
Dispenser Motor
-
51
-
Содержание LMXS27626S
Страница 4: ... 4 ...
Страница 5: ...Top Drawer Bottom Drawer 5 ...
Страница 20: ...5 CIRCUIT DIAGRAM 5 ...
Страница 23: ... P N EBR60070711 33 7 PCB Picture 7 3 Sub PCB 23 ...
Страница 73: ... 73 10 COMPONENT TESTING INFORMATION 10 1 ...
Страница 101: ...136B 131A 251A 251B 203C 136A 237C FREEZER PARTS CAUTION Use the part number to order part not the position number ...
Страница 106: ...600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J 607A ...
Страница 107: ......