-29-
9-2. Interlock Continuity Test
A. PRIMARY INTERLOCK SWITCH TEST
When the door is opened slowly, an audible
click
should be heard at the same time or successively
at intervals and the latches should activate the
switches with an audible
click.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure.
Disconnect the wire lead from the primary switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminal of the
switch. The meter should indicate an open circuit
in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are
connected correctly.
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO.SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO.SZM-V16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO.SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH
NO
COM
NC
COM
NO
COM
Содержание LMV1683SB
Страница 7: ... 7 4 OPERATION 4 1 Control Panel 2 4 11 10 3 1 8 12 9 15 18 19 17 14 20 13 16 7 6 5 ...
Страница 9: ... 9 5 WIRING DIAGRAM KEY MATRIX 5 1 Wiring Diagram ...
Страница 10: ... 10 5 2 Key Matrix KEY MATRIX ...
Страница 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Страница 16: ... 16 Keypad Failure ...
Страница 18: ... 18 No Heat No Cook ...
Страница 42: ... 43 DOOR PARTS II 1005 1000 1002 1004 1006 1007 1008 1381 W262 1009 EV Customer Model Product Code SVC Model ...
Страница 43: ... 45 2004 2381 2008 2006 W102 2018 EV Customer Model Product Code SVC Model CONTROLLER PARTS II ...
Страница 45: ... 47 LATCH BOARD PARTS 4001 W102 4000 4002 4003 4002 4004 EV ...
Страница 46: ... 48 INTERIOR PARTS I 5008 5035 W101 5016 5034 5000 5002 5018 W101 3009 3008 3012 3002 3037 5014 W101 5009 EV ...
Страница 47: ... 49 INTERIOR PARTS II 5024 3027 3028 5045 5037 5038 5010 5001 W101 5058 5044 3004 5043 5337 5006 5041 5118 EV ...
Страница 48: ... 50 INSTALLATION PARTS 6008 6011 6010 VINYL BAG 6009 EV ...
Страница 49: ......