-12-
A. SINCE NEARLY 4,000 VOLTS EXISTS IN
SOME CIRCUITS OF THIS UNIT REPAIRS
SHOULD BECARRIED OUT WITH GREAT
CARE.
The filament leads of magnetron carry High
Voltage with respect to ground. Extreme caution
must be exercised. Never plug the unit into a
power source to determine which component is
defective in high voltage section.
B. TO AVOID POSSIBLE EXPOSURE TO
MICROWAVE ENERGY LEAKAGE, THE
FOLLOWING PRECAUTIONS MUST BE
TAKEN
BEFORE SERVICING.
(1) Before the power is applied:
(a) Make sure the primary interlock switch, the
secondary interlock switch and the interlock
monitor switch operate properly by opening
and closing the door several by opening and
closing the door several times.
(b) Make sure the perforated screen and the
dielectric choke of the door are correctly and
firmly mounted.
(2) After power is applied:
(a) Make sure the interlock switch mechanism
is operating properly by opening and closing
the door.
(b) Check microwave energy leakage must be
below the limit of 5 mW/cm
2
.
(All service adjustments should be made for
minimum microwave energy leakage
readings).
(3) Do not operate the unit until it is completely
repaired, if any of the following conditions exist.
The unit must not be operated.
(a) The door does not close firmly.
(b) The hinge is broken.
(c) The door seal is damaged.
(d) The door is bent or warped, or there is any
other visible damage on the unit that may
cause microwave energy leakage.
NOTE:
Always keep the seal clean.
(e) Make sure that there are no defective parts
in the interlock mechanism.
(f) Make sure that there are no detective parts
in the microwave generating and
transmission
assembly (especially waveguide).
(4) The following items should be checked after the
unit is repaired:
(a) The interlock monitor switch is connected
correctly and firmly.
(b) The magnetron gasket is properly positioned
and mounted.
(c) The waveguide and the oven cavity are
intact.
(no microwave energy leakage)
(d) The door can be properly closed and the
safety switches work properly.
(e) The unit must stop when the door is opened
or the time is up.
The unit must not be operated with any of the above
components removed or bypassed.
6-2. Safety Caution
Содержание LMV1683SB
Страница 7: ... 7 4 OPERATION 4 1 Control Panel 2 4 11 10 3 1 8 12 9 15 18 19 17 14 20 13 16 7 6 5 ...
Страница 9: ... 9 5 WIRING DIAGRAM KEY MATRIX 5 1 Wiring Diagram ...
Страница 10: ... 10 5 2 Key Matrix KEY MATRIX ...
Страница 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Страница 16: ... 16 Keypad Failure ...
Страница 18: ... 18 No Heat No Cook ...
Страница 42: ... 43 DOOR PARTS II 1005 1000 1002 1004 1006 1007 1008 1381 W262 1009 EV Customer Model Product Code SVC Model ...
Страница 43: ... 45 2004 2381 2008 2006 W102 2018 EV Customer Model Product Code SVC Model CONTROLLER PARTS II ...
Страница 45: ... 47 LATCH BOARD PARTS 4001 W102 4000 4002 4003 4002 4004 EV ...
Страница 46: ... 48 INTERIOR PARTS I 5008 5035 W101 5016 5034 5000 5002 5018 W101 3009 3008 3012 3002 3037 5014 W101 5009 EV ...
Страница 47: ... 49 INTERIOR PARTS II 5024 3027 3028 5045 5037 5038 5010 5001 W101 5058 5044 3004 5043 5337 5006 5041 5118 EV ...
Страница 48: ... 50 INSTALLATION PARTS 6008 6011 6010 VINYL BAG 6009 EV ...
Страница 49: ......