A. PRIMARY INTERLOCK SWITCH TEST
When the door is opened slowly, an audible
click
should be heard at the same time or successively
at intervals and the latches should activate the
switches with an audible
click.
If the latches do not activate the switches when the
door is closed, the switches should be a adjusted in
accordance with the adjustment procedure.
Disconnect the wire lead from the primary switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminal of the
switch. The meter should indicate an open circuit
in the door open condition.
When the door is closed, the meter should indicate
a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit
in the door open condition. When the door is
closed, meter should indicate an closed circuit.
When the secondary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit
in the door open condition. When the door is
closed, meter should indicate an open circuit.
When the monitor switch operation is abnormal,
replace with the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
7-14
INTERLOCK CONTINUITY TEST
COMPONENTS TEST
PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE: After checking for the continuity of switches, make sure that they are
connected correctly.
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO. SZM-V16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH
NO
COM
NC
COM
NO
COM
Содержание LMV1640DB
Страница 7: ...4 1 OPERATING INSTRUCTIONS CONTROL PANEL ...
Страница 9: ...5 1 OVERALL CIRCUIT DIAGRAM SCHEMATIC DIAGRAM ...
Страница 36: ...8 1 EXPLODED VIEW DOOR PARTS 13581A 13552A 13536A 13213A 14890A 13720D 13650A 14970A 14026A WTT028 ...
Страница 37: ...8 2 CONTROLLER PARTS 24810P 23572A 23506A 07 268711 24781M WTP018 ...
Страница 39: ...8 4 466001 43500A 466003 466001 44510A 43501A WSZ084 LATCH BOARD PARTS ...
Страница 42: ...8 7 INSTALLATION PARTS 63300M 65862D 65862B 63861A ...
Страница 43: ...8 12 SCHEMATIC DIAGRAM OF P C B ...
Страница 44: ...8 13 PRINTED CIRCUIT BOARD ...
Страница 45: ......