– 10 –
STEP 3:
PREPARE THE VENT MOTOR
Your microwave oven is shipped with the blower assembled for room venting. If you want wall-venting
or roof-vented installation, you must change the blower, as detailed below.
●
DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring
could result in electrical shock.
ROOM-VENTED (Recirculating)
INSTALLATION:
This oven is shipped assembled for room-vented.
ROOF-VENTED INSTALLATION:
1. Remove ventgrille by removing two screws on the
ventgrille.
2. Turn two mounting rods anti-clockwise with flat blade
screwdriver and take off the mounting plate from the
unit. See figure 10.
3. Detach mount-all from out case by removing two
mount-all mounting screws and one motor mounting
screw. See figure 11.
4. Keep the motor wire being connected , lift up, rotate
and reattach the motor so that the exhaust ports face
the upper of the cabinet. See figure 12.
5. Use side cutters or tin snips to cut and remove
knockouts from mount-all. Be careful not to distort the
plate. See figure 13.
6. Reattach the mount-all on the cabinet with three
screws.
ELECTRICAL SHOCK HAZARD!
UNPLUG UNIT BEFORE WORKING ON IT.
W A R N I N G
mount-all
mounting screws
mount-all
motor
mounting screw
Vent motor
back plate
exhaust ports
motor wire
Vent Grille
Controller
Mounting
Plate
Mounting
Rod
Door
Out Case
Mount-all
Flat blade
screw driver
(2-screw positions
are optional.)
Remove
mounting
plate.
Figure 10
Figure 11
Figure 12