MULTI F OUTDOOR UNIT | 27
Multi F Outdoor Unit Data
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F
Table 20:
LMU36CHV with Non-Ducted Indoor Units — Rated Cooling Combination Table.
No. of
Indoor
Units
Indoor Unit Combination
(kBtu/h)
Room Capacity
Total Capacity
Input (W)
EER SEER
IDU
1
IDU
2
IDU
3
IDU
4 Total
Unit 1
(Btu/h)
Unit 2
(Btu/h)
Unit 3
(Btu/h)
Unit 4
(Btu/h)
Minimum
Rated
Maximum
Min. Rated Max.
Btu/h
kW
Btu/h
kW
Btu/h
kW
Non-Ducted Indoor Units
Three
Units
12 12 18
-
42 9,143 9,143 13,714
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
12 15 15
-
42 9,143 11,429 11,429
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
7 12 24
-
43 5,209 8,930 17,860
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
7 18 18
-
43 5,209 13,395 13,395
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
9 12 24
-
45 6,400 8,533 17,067
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
9 18 18
-
45 6,400 12,800 12,800
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
12 15 18
-
45 8,533 10,667 12,800
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
15 15 15
-
45 10,667 10,667 10,667
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
7 15 24
-
46 4,870 10,435 16,696
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
9 15 24
-
48 6,000 10,000 16,000
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
12 12 24
-
48 8,000 8,000 16,000
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
12 18 18
-
48 8,000 12,000 12,000
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
15 15 18
-
48 10,000 10,000 12,000
-
19,200 5.63 32,000 9.38 36,800 10.79 1,806 2,580 3,612 12.4 21.0
Four
Units
7
7
7
7
28 7,000 7,000 7,000 7,000 16,800 4.92 28,000 8.21 33,600 9.85 1,540 2,200 3,080 12.7 21.5
7
7
7
9
30 7,000 7,000 7,000 9,000 18,000 5.28 30,000 8.79 36,000 10.55 1,645 2,350 3,290 12.8 21.6
7
7
9
9
32 7,000 7,000 9,000 9,000 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
7 12 33 6,788 6,788 6,788 11,636 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9
9
9
34 6,588 8,471 8,471 8,471 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
9 12 35 6,400 6,400 8,229 10,971 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
7 15 36 6,222 6,222 6,222 13,333 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9
9
9
36 8,000 8,000 8,000 8,000 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9
9 12 37 6,054 7,784 7,784 10,378 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
9 15 38 5,895 5,895 7,579 12,632 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7 12 12 38 5,895 5,895 10,105 10,105 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
7 18 39 5,744 5,744 5,744 14,769 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9
9 12 39 7,385 7,385 7,385 9,846 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9
9 15 40 5,600 7,200 7,200 12,000 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9 12 12 40 5,600 7,200 9,600 9,600 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
9 18 41 5,463 5,463 7,024 14,049 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7 12 15 41 5,463 5,463 9,366 11,707 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9
9 15 42 6,857 6,857 6,857 11,429 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9 12 12 42 6,857 6,857 9,143 9,143 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9
9 18 43 5,209 6,698 6,698 13,395 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9 12 15 43 5,209 6,698 8,930 11,163 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7 12 12 12 43 5,209 8,930 8,930 8,930 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7 12 18 44 5,091 5,091 8,727 13,091 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7 15 15 44 5,091 5,091 10,909 10,909 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
7 24 45 4,978 4,978 4,978 17,067 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9
9 18 45 6,400 6,400 6,400 12,800 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9 12 15 45 6,400 6,400 8,533 10,667 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9 12 12 12 45 6,400 8,533 8,533 8,533 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9 12 18 46 4,870 6,261 8,348 12,522 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
9 15 15 46 4,870 6,261 10,435 10,435 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7 12 12 15 46 4,870 8,348 8,348 10,435 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7
9 24 47 4,766 4,766 6,128 16,340 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
7
7 15 18 47 4,766 4,766 10,213 12,255 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9 12 18 48 6,000 6,000 8,000 12,000 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
9
9 15 15 48 6,000 6,000 10,000 10,000 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
12 12 12 12 48 8,000 8,000 8,000 8,000 19,200 5.63 32,000 9.38 38,400 11.25 1,723 2,461 3,445 13.0 22.0
1
Capacity as rated:
0 ft. above sea level with 25 ft. of refrigerant piping.
0 ft. level difference between outdoor and indoor units.
2
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
3
Wiring cable size must comply with the applicable local and national codes.
4
The specification may be subject to change without prior notice for purpose of improvement.
5
At least two indoor units should be connected.
Rated Cooling Combination Tables
PERFORMANCE DATA