8-1-9 Electrical Parts Are Turned On Sequentially
Electrical parts such as compressor, defrosting heater, freezer fan, etc. are turned on in the following order to prevent noise
and parts damage. Several parts are started at the same time at initial power on and are turned off together when test is
completed.
OPERATING
ORDERS
Temperature of defrosting
sensor is 45°C or more
(when unit is newly
purchased or when moved)
Power
ON
Freezer fan
ON
Compressor
ON
Temperature of defrosting
sensor is lower than 45°C
(during power outages or
for service)
Reset to normal operation
from test mode
Initial power on
in 0.5 sec
in 0.5 sec
Power
ON
Defrosting
heater OFF
Defrosting
heater ON
in 0.5 sec
in 10 sec
Door
heater OFF
Door
heater ON
in 0.5 sec
in 5 sec
Freezer fan
ON
Compressor
ON
in 0.5 sec
in 0.5 sec
Total
load OFF
Freezer fan
ON
Compressor
ON
in 7 min
in 10 min