5-9
INTERLOCK CONTINUITY TEST
A. PRIMARY INTERLOCK SWITCH TEST
When the door is pulled slowly with the door closed, an audible click
should be heard at the same time or successively at intervals. When the
door is closed slowly, the latches should activate the switches with an
audible click. If the latches do not activate the switches when the door is
closed, the switches should be a adjusted in accordance with the
adjustment procedure. Disconnect the wire lead from the primary switch.
Connect the ohmmeter leads to the common (COM) and normally open
(NO) terminal of the switch. The meter should indicate an open circuit in
the door open condition.
When the door is closed, the meter should indicate a closed circuit.
When the primary switch operation is abnormal, make the necessary
adjustment or replace the switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary switch.
Connect the ohmmeter leads to the common (COM) and normally open
(NO) terminals of the switch. The meter should indicate a open circuit in
the door open condition. When the door is closed, meter should indicate
an closed circuit. When the secondary switch operation is abnormal, make
the necessary adjustment or replace the switch only with the same type of
switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch. Connect the ohmmeter
leads to the common (COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in the door open condition.
When the door is closed, meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with the same type of
switch. Check Common and normally open terminals,too. Opposite result
of Common-normally close test is normal.
NOTE: After repairing the door or the interlock system, it is
necessary to do this continuity test before operating the oven.
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION EMISSION, REPLACE ONLY WITH
IDENTICAL REPLACEMENT PARTS.
TYPE NO.SZM-V 16-FA-63 FOR PRIMARY SWITCH / TYPE NO.SZM-V 16-FA-61 FOR MONITOR SWITCH / TYPE NO.SZM-V 16-FA-63 FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
(Wire leads removed)
Check for continuity of the switch with an Ohm-meter
Door open
Door closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are connected correctly.
NO
COM
NC
NC
COM
NO
NO
COM
NO
COM
NO
COM
NC
NC
COM
NO
NO
COM
NO
COM
NO
COM
NC
NC
COM
NO
NO
COM
NO
COM
NO
COM
NC
NC
COM
NO
NO
COM
NO
COM
Содержание LMC1575BD
Страница 8: ...4 1 FEATURES OPERATING INSTRUCTIONS ...
Страница 11: ...4 4 SCHEMATIC DIAGRAM ...
Страница 46: ...5 34 Inverter supporter upper type Inverter supporter lower type A B C D E ...
Страница 49: ...DOOR PARTS EV 1005 1000 1004 1002 1007 1006 1384 1114 ...
Страница 50: ...CONTROL PANEL PARTS EV 2006 2002 2000 2001 2004 ...
Страница 51: ...OVEN CAVITY PARTS EV 3001 3034 3002 3012 3009 3161 W607 3008 ...
Страница 52: ...LARCH BOARD PARTS EV 4001 NSP No Service Parts W509 ...
Страница 53: ...INTERIOR PARTS EV 5003 5014 5041 5007 5012 5010 W520 W140 5001 5016 5009 5006 W101 W101 5004 5011 ...
Страница 54: ...BASE PLATE PARTS EV 5474 6100 6007 6011 5473 W520 507V 5471 5472 6001 W701 ...
Страница 55: ......