CIRCUIT DESCRIPTION
GENERAL DETAILS
• The SMPS supplies the necessary voltage to the micom controller when power
cord is plugged in.
• When the door is closed, the primary switch is ON, the secondary switch is ON,
and the monitor switch opens (contact COM and NO).
WHEN SELECTING COOKING POWER LEVEL AND TIME
• The micom controller memorizes the function you set.
• The time you set appears in the display window.
• Each indicator light turns on to indicate that the stage has been set.
WHEN TOUCHING THE START BUTTON
• The coil of the relay is energized by the micom controller.
• Power input is supplied to the Inverter PCB through the fuse to the primary
switch and relay 2 .
• Turntable rotates.
• The fan motor rotates and cools the magnetron by blowing the air (coming from
the intake on the Back-plate).
FUSE
MICOM CONTROLLER
SECONDARY
SWITCH
PRIMARY
SWITCH
MONITOR
SWITCH
L
N
RELAY 2
inverter
• The air is also directed into the oven to exhaust the vapor in the oven through
the Left side plate.
• Cooking time starts counting down.
• 3.3 volts AC is generated from the filament winding of the inverter PCB. This 3.3
volts is applied to the magnetron to heat the magnetron filament through two
noise-preventing choke coils.
• The inverter PCB generates high voltage of approximately 4,000V negative DC.
The voltage is applied to the filament of the magnetron.
WHEN THE OVEN IS SET AT POWER LEVEL
• The inverter control micro wave out-put power from 100 % to 30 % by controlling
power consumption.
20% and 10% Power are controlled by relay on/off working.
• One complete cycle of relay 32 seconds.
WHEN THE DOOR IS OPENED DURING COOKING
• Both the primary switch and relay cut off input voltage of inverter PCB.
• ON-OFF of relay is coupled electrically with opening and closing of the
secondary switch.
• When the door is opened, the secondary switch is opened and when the door is
closed, the secondary switch is closed.
• The cooking time stops counting down.
• Relay stops functioning.
• As the door is opened, if the contact of primary switch and relay 2 and/or
secondary switch fail to open, the fuse opens due to the large current surge
caused by the monitor switch activation, which in turn stops magnetron
oscillation.
FUSE
PRIMARY
SWITCH
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
MONITOR
SWITCH
L
N
inverter
FUSE
PRIMARY
SWITCH
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
MONITOR
SWITCH
L
N
inverter
FUSE
PRIMARY
SWITCH
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
MONITOR
SWITCH
L
N
inverter
FUSE
PRIMARY
SWITCH
RELAY 2
MICOM CONTROLLER
SECONDARY
SWITCH
MONITOR
SWITCH
L
N
inverter
Door open
Содержание LMC1575BD
Страница 8: ...4 1 FEATURES OPERATING INSTRUCTIONS ...
Страница 11: ...4 4 SCHEMATIC DIAGRAM ...
Страница 46: ...5 34 Inverter supporter upper type Inverter supporter lower type A B C D E ...
Страница 49: ...DOOR PARTS EV 1005 1000 1004 1002 1007 1006 1384 1114 ...
Страница 50: ...CONTROL PANEL PARTS EV 2006 2002 2000 2001 2004 ...
Страница 51: ...OVEN CAVITY PARTS EV 3001 3034 3002 3012 3009 3161 W607 3008 ...
Страница 52: ...LARCH BOARD PARTS EV 4001 NSP No Service Parts W509 ...
Страница 53: ...INTERIOR PARTS EV 5003 5014 5041 5007 5012 5010 W520 W140 5001 5016 5009 5006 W101 W101 5004 5011 ...
Страница 54: ...BASE PLATE PARTS EV 5474 6100 6007 6011 5473 W520 507V 5471 5472 6001 W701 ...
Страница 55: ......