- 36 -
CON3
Symptom
Check Point
1. F dH
1. Check the door gasket
2. Check the defrost control parts
3. Check the PCB output voltage
4. Check defrost heater
Defrost Control Parts
Defrost
Heater #1
Fuse-M
Defrost
Sensor
Defrost
Heater #2
Part
Resistance [Ω]
FUSE-M
0.2 ↓
Defrost Heater
(1) 60 ~ 70
(2) 140 ~ 170
Total Heater
Resistance
40 ~ 50
Defrost Sensor
22k↑
TEST MODE 3
Voltage [V]
CON3
3
rd
- 10
th
pin
110 ~ 120
TEST MODE 1
Voltage [V]
CON3
3
rd
- 10
th
pin
0V
8-6. Defrost Heater Error (F dH)