![LG LFXS27466S Скачать руководство пользователя страница 83](http://html.mh-extra.com/html/lg/lfxs27466s/lfxs27466s_service-manual_1903282083.webp)
- 58 -
B3. LED blinks five times, then repeats (Locked Piston)
Protection Logic
Protection Logic
Blink Blink Blink Blink Blink OFF
Protection
logic
Check B
Blink 5 times
(Lock Piston Trip) Check B3
Compressor
Doesn’t work
Repeat
Check Procedure
Reset
Power
Compressor
Doesn’t work
N
Y
Replace
Compressor
Hi side
restriction
N
Y
Sealed
system
Repair
- Purpose: To detect locked piston
- Cause: Lack of oil to the cylinder, cylinder or piston damaged and or restricted discharge.
A Locked Piston can also be caused by foreign materials inside the compressor.
- Logic: Compressor is forced off and tries to restart within 2.5 minutes.
B4. LED blinks six times, then repeats (Current Trip)
Blink
Blink
Blink Blink Blink Blink
OFF
Protection
logic
Check B
Blink 6 time
(Current Trip) Check B4
Compressor
Intermittently
works
Y
Capacitor
Spec.
Check C2
Compressor
Damage
Check C3
Replace
Capacitor
Replace
Compressor
NG
NG
Reset
Power
Y
Current trip
Occur?
Y
Repeat
Check Procedure
IPM
Check B5
Y
Replace
Driver PCB
NG
N
Y
N
Cycle
Check E
Y
Fix
Cycle
- Purpose: Prevent over-current (overload protect)
- Cause: Ambient temperature is high (over 43°C) and/or refrigerator’s condenser air movement is restricted.
- Condenser Fan is stopped, restricted discharge line, compressor is damaged, or IPM device is defective.
- Logic: Compressor is forced off and tries to restart after 6 minutes.
Содержание LFXS27466S
Страница 4: ......
Страница 18: ... 20 5 CIRCUIT DIAGRAM ...
Страница 21: ... P N EBR60070711 33 7 PCB Picture 7 3 Sub PCB ...
Страница 104: ...279B 276A 276B 405A 276F 276G 275A 279I 279H 279J 402C 281A 279D 500C 279E 501A 279A 279C 281B 501D 278C 278D ...
Страница 105: ...617A 616G 625A 616J 623B 616J 627B 623B 627A 619A ...
Страница 106: ...600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J ...
Страница 107: ...Jun 2014 Printed in China ...