- 57 -
12-2 Check B
B1. LED blinks once, then repeats (FCT0 Fault)
- Purpose: Detecting motor current and voltage error
- Check voltage at
point A
(Motor Voltage),
point B
(Motor Current) and
Point C
(Capacitor
Voltage) when
compressor is off
.
- Spec:
Points A, B,
&
C 2.5V
±
0.3V
Protection Logic
Blink
OFF Blink OFF
Y
N
Protection
logic
Check B
Blink 1 time
(FCT 0) Check B1
Out of spec?
(2.2 - 2.8V)
Reset Power
Replace Driver PCB
B2. LED blinks two times, then repeats (Stroke Trip)
Protection Logic
Blink
Blink OFF Blink Blink OFF
Y
Y
Y
Y
Protection
logic
Check B
Blink 2 times
(Stroke Trip) Check B2
Compressor
Doesn’t work
Y
N
Compressor
Works Intermittently
Capacitor
Spec.
Check C
Compressor
Damage
Check C
Replace
Capacitor
Replace
Compressor
N
N
Reset
Power
Stroke Trip
Occur?
Y
Repeat
Check Procedure
Harness
Connecting
Check C
Fix Harness
N
N
Cycle
Check E
Fix
Cycle
Replace
Driver PCB
OK
NG
- Purpose: Prevent abnormally long piston strokes.
- Case 1. If compressor doesn’t work and LED blinks - Cause: Possibly harness from compressor to PCB might be
defective.
- Case 2. If compressor works intermittently and LED blinks - Cause: Condenser Fan or Freezer Fan is not running. Sealed
system problem such as moisture restriction, restriction at capillary tube or refrigerant leak.
- Logic: Compressor is forced to off and then tries to restart after 1 minute.
GND
Voltage
A
B
C
Содержание LFXS27466S
Страница 4: ......
Страница 18: ... 20 5 CIRCUIT DIAGRAM ...
Страница 21: ... P N EBR60070711 33 7 PCB Picture 7 3 Sub PCB ...
Страница 104: ...279B 276A 276B 405A 276F 276G 275A 279I 279H 279J 402C 281A 279D 500C 279E 501A 279A 279C 281B 501D 278C 278D ...
Страница 105: ...617A 616G 625A 616J 623B 616J 627B 623B 627A 619A ...
Страница 106: ...600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J ...
Страница 107: ...Jun 2014 Printed in China ...