- 39 -
8-10 Icing Fan Error (Er IF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the air
flow.
3
Check the Connector.
(Frozen caused the PCB short)
Result & SVC Action
Status
No windy
Windy
SVC Action
Go to the 3,4
Go to the 5
4
Check the Fan motor voltage.
Below 9 V
0 or 5 V
(1) ~ (2)
(1) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON7>
(3) (2) (1)
Содержание LFX25992 series
Страница 26: ... 26 5 CIRCUIT DIAGRAM ...
Страница 28: ... 28 7 PCB PICTURE 7 1 Main PCB P No MFG EBR730936 2011 01 Picture CON2 CON3 CON1 CON5 CON6 CON7 ...
Страница 29: ... 29 7 2 Display PCB Sub PCB P No Display PCB EBR 729554 2011 03 Sub PCB EBR60070709 2011 01 Picture ...
Страница 95: ...P No MFL67655010 NOV 2012 Printed in Korea ...