- 17 -
3-19 WATER VALVE DISASSEMBLY METHOD
1) Turn off the water to unit. Remove the waterline from the
valve.
3-20 FAN AND FAN MOTOR DISASSEMBLY
METHOD
1) Remove screws for the Drain Pipe Assembly and the 1
connected to the Motor Cover.
2) Remove cover and 1 screw from the valve.
3) Separate the housing and remove the valve.
4) Remove the clip, and press the collet to separate the
tube from the connector. Note: there maybe some water
in the line.
Mechanical Cover
Housing
MOTOR COVER
2) Separate the Fan Assembly and Motor, turn counter
clockwise to remove from the motor shaft.
FAN ASSEMBLY
MOTOR
Assemble in reverse order. Taking care to avoid.
1. Do not to bend the tube during assembly.
2. Press the Water Dispenser button letting water pour out,
this checks for any leaks in the tube connection, this may
vary depending on the water pressure
( about 2 minutes.).
Содержание LFX25992 series
Страница 26: ... 26 5 CIRCUIT DIAGRAM ...
Страница 28: ... 28 7 PCB PICTURE 7 1 Main PCB P No MFG EBR730936 2011 01 Picture CON2 CON3 CON1 CON5 CON6 CON7 ...
Страница 29: ... 29 7 2 Display PCB Sub PCB P No Display PCB EBR 729554 2011 03 Sub PCB EBR60070709 2011 01 Picture ...
Страница 95: ...P No MFL67655010 NOV 2012 Printed in Korea ...