background image

Installation Manual

Electric Range

LFRF0222S

Please read these instructions thoroughly before
installing and operating the range.

P/No.: MFL40441501

Содержание LFRF0222S

Страница 1: ...InstallationManual Electric Range LFRF0222S Please read these instructions thoroughly before installing and operating the range P No MFL40441501 ...

Страница 2: ... homes recreational vehicles and installations where local codes do not allow grounding through the neutral wire require a 4 conductor UL listed range cord or 4 wire conduit connection The middle neutral or ground wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block The remaining two wires of the power cord or conduit have to be connecte...

Страница 3: ...rings around the range can withstand the heat generated by the range To eliminate the need to reach over the surface elements cabinet storage space above the elements should be avoided TOOLS NEEDED PREPARE TO INSTALL THE RANGE PARTS NOT PROVIDED WARNING The information in this manual should be followed exactly A fire or electrical shock may result causing property damage perasonal injury or death ...

Страница 4: ...ss steel 0 024 0 610 mm aluminum or 0 020 0 508 mm copper 15 38 1 cm minimum between countertop and adjacent cabinet bottom FIGURE 1 FIGURE 2 A 30 76 2 cm For U S A 30 76 2 cm 31 78 7 cm For CANADA CAUTION Make sure that the wall covering countertop and cabinets around the range can withstand the heat up to 194 F generated by the range Discoloration delamination or melting may occur This range has...

Страница 5: ... accordance with the National Electrical code ANSI NFPA NO 70 latest edition All wiring should conform to Local and NEC This range requires a single phase 3 wire A C 120 208V or 120 240V 60Hz electrical system Use only a 3 conductor or a 4 conductor UL listed range cord with closed loop terminals open end spade lugs with upturned ends or similar terminations Cord must have the strain relief proper...

Страница 6: ...ctrical shock severe personal injury or death Install the power cord as follows For power cord installations Hook the strain relief over the power cord hole 13 8 located below the rear of drawer body Insert the power cord through the strain relief and tighten it Refer to Figure 7 You must install the power cord with a strain relief 1 Remove the lower 3 screws from the terminal block and retain the...

Страница 7: ...n relief with its ring Reinstall the bracket For conduit connections If the wire in the conduit is copper it must be 8 or 10 AWG wiring If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring 1 Loosen the lower 3 screws from the terminal block Refer to Figure 11 2 Insert the bare wire white neutral end through the center terminal block opening Do not remove ground strap connections 3 I...

Страница 8: ...3 Remove ground strap and discard as shown in Figure 12 Do not discard any screws 4 Attach the ground bare wire end to range frame and secure it in place with the ground screw Refer to figure 12 5 Insert the bare wire white neutral end through the center terminal block opening 6 Insert the two side bare wire ends into the left and the right terminal block opening Tighten the 3 screws securely into...

Страница 9: ...evel on the rack adjust the leveling legs with a wrench FINAL INSTALLATION Move range close enough to the opening to plug into the receptacle Slide range into position insuring that the left back leg slides under the anti tip bracket Range will sit 0 away from the back wall when properly installed Carefully tip range forward to insure that the anti tip bracket engages the range back brace and prev...

Страница 10: ......