- 21 -
8-7 Condenser Fan Error (Er CF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Check the fan rotating.
While an error code is displayed,
the fan is not working.
3
Check the Fan motor and surrounding.
Rotate fan using your hand.
It feel sticky, change the motor.
Result & SVC Action
4
Check the Fan motor voltage.
Below 9 V
0 or 5 V
(1) ~ (2)
(2) ~ (3)
Change the PCB
Change the motor
Result
SVC Action
Status
No windy
Windy
SVC Action
Check motor
Go to the 4
<CON7>
(3)
(2)
(1)