- 22 -
No
8-6 Freezer Fan Error (Er FF)
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the
air flow.
While an error code is displayed,
the fan is not working.
3
Check the Fan motor.
Rotate fan using your hand.
It feel sticky, change the motor.
(Cause of ice or rust inside of motor)
4
Check the Fan motor voltage.
Result & SVC Action
Below 9 V
0 or 5 V
(1) ~ (2)
(2) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON4>
Status
No windy
Windy
SVC Action
Go to 3
Go to 4
(1) (2) (3)
Содержание LFC21776ST
Страница 13: ... 13 5 CIRCUIT DIAGRAM ...
Страница 15: ... 15 7 PCB Picture 7 1 Main PCB P No MFG EBR67348002 2010 03 Picture CON4 CON5 CON8 CON3 CON2 CON9 CON1 ...
Страница 16: ... 16 7 2 Display PCB Sub PCB P No Display PCB EBR42479305 2010 03 Picture CON01 ...
Страница 62: ...P No MFL47912326 ...