- 34
-
PROBLEM
INDICA
TED BY
CHECK
CHECKING METHOD
CAUSE
SOLUTION
COOLING is poor
.
If REFRIGERA
TOR
1.If
FREEZER TEMPERA
TURE
Check is FREEZER
Make sure the
TEMPERA
TURE
isn ormal.
TEMPERA
TURE is
too low
.
DOOR isattached.
is too low
.
2. If amount of cool air from
Make sure that the amount
FAN MOTOR is poor
.
Replace F
AN MOTOR.
FAN MOTOR is
and speed of cool air are
P
assage of cool air
Remove impurities.
sufficient.
sufficient by touching the
is blocked.
check supplied on the
EV
A frozen.
See
DEFROSTING is poor
.
REFRIGERA
TOR.
3. Door Line contact.
Check door seal when
Door liner damaged.
Replace Door liner
.
door is closed.
DEFROSTING is
NO DEFROSTING.
1. If HEA
TER emits heat.
USE TEST MODE3
HEA
TER disconnection.
Replace HEA
TER.
poor
.
(forced DEFROSTING).
TEMPERA
TURE FUSE
Replace TEMPERA
TURE
disconnection.
FUSE
.
Connection is poor
.
Check EV
APORA
TOR
connection and wire of MAIN
P
WB CONNECTOR.
DEFROST
-SENSOR is poor
.
Replace DEFROST
-SENSOR.
HEA
TER RELA
Y is poor
.
Replace RY2 of MAIN P
WB.
2. If DRAIN PIPE is
Check DRAIN PIPE
.
DRAIN PIPE is blocked.
Remove ice and impurities.
blocked.
Check HEA
TER PLA
TE
resistance.
3. If ice remains after
Make sure that DEFROST
Connection is poor
.
Reassemble the
DEFROSTING.
SENSOR is connected.
DEFROST
-SENSOR.
Make sure that FREEZER /
DOOR does not close
Reassemble DOOR.
REFRIGERA
TOR DOOR is closed.
properly
.
Replace GASKET
.