16
Before use
Bef
or
e use
2
RS-485 connection
①
This device has 1 data port (RS-485).
②
Use this port to connect the PTZ camera or the
keypad. (Optional)
③
PTZ camera / keyboard connection
i. Connect the PTZ serial communication cable to
the RS-485 port.
ii. When connecting the cable, make sure that
the TX- of the device is connected to the RX-
(TX-) of the camera(keyboard), and TX+ of the
device is connected to the RX+(TX+) of the PTZ
camera(keyboard).
iii. Recommended initial data setting is 9 600 baud
rate, 8 data bits, 1 stop bit and no parity.
iv. When connecting the PTZ camera or keyboard, always change the setting of the DVR
setting menu according the RS-485 setting of the camera, keyboard and this device.
v. Set the same baud rate when you are to use PTZ camera and keyboard at the same time
Control port (Output) connection
①
For interface and auto control with the external sensor, the interfacing control output port
(Set value from “Setup
Ò
Event
Ò
Sensor/Motion/Video loss” menu) and the “RELAY” port are
connected.
②
If the control device (Alarm light, amplified siren, external relay etc.) is “NC (Normal Close)” type,
connect to the control output NC (Normal Close) port.
③
If the control device (Alarm light, amplified siren, external relay etc.) is “NO (Normal Open)” type,
connect to the control output NO (Normal Open) port.