For Authorized Service Technicians
- 48 -
EXCESS ERROR
displayed
Condition
Water fills above normal
level(Automatically
drainPump operated.)
1) The Inlet Valve is damaged.
2) The Controller is damaged.
3) After Replace the PCB, still same
Error code is displaying.
1) Replace the Inlet Valve.
2) Replace the Controller.
3) Replace the Hole Sensor.
THERMAL ERROR
displayed
Condition
Thermistor resistance
output abnormal
1) Wiring connection is OK?
2) The Thermistor is OK?
1) Check and reconnect the wire.
2) Check the electric resistance of
Thermistor.
HEATER ERROR
displayed
Condition
The water is not heated
or the temperature in
the Tub is overheated to
over 194℉
1) Wiring connection is OK?
2) The Inlet Water Temperature is very
high.
3) The Thermistor is damaged.
4) Heater is OK?
5) The Controller is damaged.
6) The Relay Circuit is OK?
1) Check and reconnect the wire.
2) Check the temperature.
① If the temperature is displayed,
adjust the Inlet Water Temperature
to 120℉ .
3) Check the electric resistance of
Thermistor.
4) Check the electric resistance of Heater.
Replace the Pump casing assembly.
5) Replace the Controller.
6) Replace the Relay Circuit.
MOTOR ERROR
displayed
Condition
The Motor is
workingabnormally
1) Wiring connection is OK?
(Washing Motor and Controller)
2) The Impeller of Washing Pump is
locked.
3) Is the Washing Motor is OK?
4) The Controller is damaged.
1) Check and reconnect the wire.
2) Replace the Pump Casing assembly.
3) Check the electric resistance of
Washing Motor.
4) Replace the Controller.
VARIO ERROR
displayed
Condition
The position of vario cam
isnot properly
1) Wiring connection is OK?
2) Does the vario S/W assembled
properly?
3) Is the vario motor operated
properly?(range is 12~15 )
1) Check and reconnect the wire.
2) Reassemble vario S/W.
3) Replace the vario motor.
Содержание LDF5545ST
Страница 2: ......
Страница 30: ...For Authorized Service Technicians 30 6 HOW TO DISASSEMBLE 1 Lower Cover 1 Remove the front 2 screws ...
Страница 73: ...For Authorized Service Technicians 73 Exploded View E005 A040 F001 M050 F101 E010 A130 LDP6797 LDP5676 ...
Страница 84: ...For Authorized Service Technicians 84 F191 F192 F193 A050 Water Guide Assembly ...
Страница 85: ...For Authorized Service Technicians 85 A050 F191 Water Guide Assembly LSDF9897 LDT7808 LSDT9908 ...
Страница 91: ...For Authorized Service Technicians 91 K200 Panel Assembly LDP6797 LDP5676 LDF5545 ...
Страница 93: ...For Authorized Service Technicians 93 K200 K210 K240 K220 Panel Assembly LUDP8997 ...
Страница 94: ...For Authorized Service Technicians 94 LUDP8997 LDP6797 LDP5676 LDF5545 K030 K217 Front Cover Assembly ...
Страница 96: ...For Authorized Service Technicians 96 K005 K030 K217 K231 K031 Front Cover Assembly LSDF9897 LSDT9908 ...
Страница 101: ...For Authorized Service Technicians 101 LSDT990 10 WIRING DIAGRAM 10 1 WIRING DIAGRAM ...
Страница 106: ...For Authorized Service Technicians 106 Appendix ...
Страница 107: ...P No MFL37554814 ...