- 8 -
3.3 TEST MODE
CHECK PROGRAM(START IN THE STATE OF THE CLOSED DOOR)
BUTTON
The number of
pushing button
DISPLAY
Load and Checking points
Delay start + Rinse
+ POWER S/W
Delay Start Key
Program Key
Half & Vario Key
Rinse Key
Start/Pause Key
1 TIME
1 TIME
1 TIME
2 TIME
3 TIME
5 TIME
6 TIME
7 TIME
1 TIME
1 TIME
1 TIME
2 TIME
3 TIME
4 TIME
5 TIME
6 TIME
7 TIME
8 TIME
9 TIME
10 TIME
11 TIME
12 TIME
13 TIME
n : 0H
11 : 11
12 : 22
13 : 33
14 : 44
16 : 66
17 : 77
18 : 88
19 : 99
10 : 00
n : 01
Frequency
n : 03
n : 04
n : 05
n : 06
n : 07
n : 08
n : 09
Temperature
n : 11
n : 12
n : 13
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
4 TIME
15 : 55
All LEDs are lighting
None
Flow Meter
Washing Motor
Drain Pump
Inlet Valve
Dispenser
Heater (for 10 sec.)
Fan Motor
Regeneration Valve
Thermister
Lower Nozzle
Upper Nozzle
AUTO OFF S/W
In & Intensive
Normal
Eco
Gentle
Quick
Pre Wash
Wash 1
Wash 2
Rinse 1
Rinse 2
Dry 1
Dry 2
※
Micro S/W must be ON to operate HEATER