- 30 -
1. This appliance must be supplied with correct rating voltage and hertz as shown on instruction manual,
and connected to an individual, properly grounded branch circuit, protected by minimum 15 amp circuit
breaker or time delay fuse.
Wiring must be 2 wires with ground.
2. The power point must be in a accessible location adjacent to and not behind the dishwasher and within
1.2 meters of the dishwasher side. A correctly rated, wired and earthed extension cord may be used if
necessary.
(See Fig. A)
3. The power point must be correctly earthed, if in doubt, have it checked by a qualified Electrician. No
other appliance shall be connected to the same plug outlet by a double adapter or similar plug.
1. Lay the dishwasher on its back.
2. Adjust the legs to the needed height of cabinet as shown at below.
Step 2 : PREPARE ELECTRICAL WIRING
Step 3 : PREPARE DISHWASHER FOR INSTALLATION
CAUTION
For personal safety, remove house fuse or open circuit breaker before installation.
Do not use an extension cord or adapter plug with this appliance.
Electrical and grounding connections must comply with the national electrical code/provincial and
municipal code and/or other local codes.
Содержание LD-2040MH