5-16
CONDITION
CHECK
RESULT
CAUSE
REMEDY
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
No microwave
oscillation.
No continuity.
Continuity.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the unit)
Defective PCB
assembly
Defective high
voltage
transformer.
Replace PCB
assembly
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective PCB
assembly
Replace PCB
assembly
Replace high
voltage
transformer.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Abnormal
normal
Check high vol-
tage transformer
Abnormal
normal
Check high vol-
tage capacitor.
Defective high
voltage diode.
Replace high
voltage diode.
Abnormal
normal
Check high vol-
tage diode.
Defective
magnetron.
Replace
magnetron.
Abnormal
Check
Magnetron.
NOTE: • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Содержание LCRT2010ST
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 28: ... 6 2 DOOR PARTS 13581A 13551A 13213A 13552A 13536A 14026A 14970A EV ...
Страница 29: ... 6 3 CONTROLLER PARTS 24781M 23550D 24510L 24970A 23551B 268711 WTP018 23551A EV ...
Страница 30: ... 6 4 OVEN CAVITY PARTS 33390G WTT020 WSZ185 33112U 35889A 36549S WTP013 33052A Button Head Torx style 2 EV ...
Страница 31: ... 6 5 LATCH BOARD PARTS WSZ085 WTT028 56912B 55262A 466001 466003 466001 43500A 43501A EV ...
Страница 33: ... 6 7 BASE PLATE PARTS 63302A WTT021 56170D WSZ002 65006B 63303A EV ...
Страница 34: ... 6 8 SENSOR PARTS 56501A WSZ002 WTP004 54974T EV ...
Страница 35: ......