Installation
Service Manual
25
4. Wiring Connection
The power cord connected to the outdoor unit
should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR
or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H05RN-F
approved by HAR or SAA).
CAUTION
20mm
GN/YL
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 2.1mm
2
(24K/38K)
Capacity
1 Phase
24K BTU/h
38K BTU/h
2.1mm
2
3.3mm
2
Make sure that the screws of the terminal are free from looseness.
WARNING
1. All wiring must comply with LOCAL REGULATIONS.
2. Select a power source that is capable of supplying the current as required by the air conditioner.
3. Feed the power source to the unit via a distribution switch board designed for this purpose.
4. The terminal screws inside the control box may be loose due to vibration during transport.
Check the screws for loose connection.
(Running the air conditioner with loose connection can overload and damage electrical components.)
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.
1Phase
Cooling Model Only.
POWER
INPUT
Terminals on the indoor unit
1(L) 2(N)
4(N)
5
7
6
8
3(L)
Terminals on the outdoor unit
4(N)
5
6
7
3(L)
Содержание LC240CP
Страница 20: ...20 Ceiling Cassette Air Conditioner Wiring Diagrams 1 Indoor Unit LCN240CP Wiring Diagrams ...
Страница 21: ...Service Manual 21 Wiring Diagrams LCU240CP LCU380CP 2 Outdoor Unit ...
Страница 53: ...Electronic Control Device Service Manual 53 Electronic Control Device Ceiling Cassette Type Main P C B ASM ...
Страница 64: ...P No 3828A20911A Printed in Korea ...