Refrigeration Cycle Diagram
–9–
Heat Pump
• If 60K Model is installed at a distance of 15m, 525g of refrigerant should be added
(15-7.5) x 70g = 525g
30K BTU/h
5/8"
3/8"
7.5
15
7.5
12.5
70
36K BTU/h
5/8"
3/8"
7.5
15
7.5
12.5
50
42K BTU/h
3/4''
3/8"
7.5
15
7.5
12.5
70
48K BTU/h
3/4''
3/8"
7.5
15
7.5
12.5
70
60K BTU/h
3/4''
3/8"
7.5
15
7.5
12.5
70
72K BTU/h
1''
1/2"
7.5
25
7.5
20
70
90K BTU/h
9/8''
5/8"
7.5
30
7.5
20
90
100K BTU/h 9/8''
5/8"
7.5
30
7.5
20
100
Capacity
Gas
Liquid
Elevation B(m)
Piping Length
A(m)
* Additional
Refrigerant
(g/m)
Pipe Size (Diam-
eter: Ø)
inch
Standard
Standard
Max.
Max.
Capacity
Orifice Number
30K
63
36K
62
42K
74
48K
86
60K
86
72K
98
90K
84
100K
104
Orifice Number
Содержание LBNK3660BL
Страница 41: ... 41 Electronic control device MAIN P C B ASM ...
Страница 65: ...Memo 65 ...
Страница 66: ... 66 Memo ...
Страница 67: ...P No 3828A20097T January 2005 Printed in Korea ...