No
7-6 Freezer Fan Error (FF E)
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the freezer door and Check the
air flow.
※
While an error code is displayed,
the fan is not working.
3
Check the
.
Fan motor
Rotate fan using your hand.
It feel sticky, change the motor.
(Cause of ice or rust inside of motor)
4
Result & SVC Action
Below 7V
0 or 5 V
(2)~(3)
(1)~(3)
Change the PCB
Change the motor