18 | Product data
Art Cool
™
Premier W
all Mounted Engineering Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
reFrigerAnT FloW diAgrAmS
Lau/Lan090HYV1, Lau/Lan120HYV1
Thermistor
Description
PCB Connector
TH1
Indoor air temperature thermistor
Cn-TH1 (Indoor)
TH2
Water level sensor (optional)
Cn-TH2 (Indoor)
TH3
Evaporator middle temperature thermistor
Cn-TH3 (Indoor)
TH4
Condensing temperature thermistor
Cn-TH1 (outdoor)
TH5
outdoor air temperature thermistor
TH6
Discharge pipe temperature thermistor
Cn-TH2 (outdoor)
FIELD PIPING
(Ø 1/ 4” Copper Tubing)
FI ELD PIPING
(Ø 3/ 8” Copper Tubing)
M
M
Heat
Exchanger
(Evaporator)
He at
Exchanger
(Condenser)
Compressor
Accumulator
2-Way Valve
Reversing
Va lve
Indoor Unit
Outdoor Unit
: Cooling
: Heating
EEV
TH1
TH3
TH2
TH5
TH6
TH4
Liqui d Side
Ga s Side
3- Way Valve