14
Multi Type Air Conditioner
Indoor Unit Installation
1. Route the indoor tubing and the drain hose in
the direction of rear left or right
2. Tape the tubing, drain hose and the
connecting cable. Be sure that the drain hose
is located at the lowest side of the bundle.
Locating at the upper side can cause drain
pan to overflow inside the unit.
Drain hose
Connecting
cable
Loop
Gas side
piping
Liquid side
piping
Drain hose
CAUTION: If the drain hose is routed inside the room, insulate the hose with
an insulation material* so that dripping from "sweating"(condensation) will
not damage furniture or floors.
*Foamed polyethylene or equivalent is recommended.
Preparing the indoor unit's piping and drain hose for installation through the wall.
3. Wall Mounted type
■
Connection of piping - Indoor