Installation Manual
19
Checking the Drainage and Forming the Piping
2) Form the pipings
1. Wrap the connecting portion of indoor unit
with the Insulation material and secure it
with two Plastic Bands. (for the right
pipings)
• If you want to connect an additional drain
hose, the end of the drain-outlet should
keep distance from the ground. (Do not
dip it into water, and fix it on the wall to
avoid swinging in the wind.)
2. Tape the Pipings, drain hose and Connecting
Cable from bottom to top.
3. Form the pipings gathered by taping along
the exterior wall and fix it onto the wall by
saddle or equivalent.
2. Tape the Pipings and Connecting cable from
bottom to top.
3. Form the pipings gathered by taping along
the exterior wall, and make the trap
prevent water from entering into the room.
4. Fix the pipings onto the wall by saddle or
equivalent.
In case of the Outdoor unit being installed
below position of the Indoor unit.
In case of the Outdoor Unit being installed
above position of the Indoor Unit.
Drain hose
Taping
Pipings
Connecting
cable
Power supply
cord
Trap is required to prevent water from entering
into electrical parts.
Seal a small opening
around the pipings
with gum type sealer.
Seal a small opening
around the pipings
with gum type sealer.
Trap
Connection of the Cable
1) Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly.
WARNING: Make sure that the screws of the terminal are free from
looseness.