3.3.2 Charging
SM-POWER provides together with an external p-channel FET Siliconix Si3455 an external AC-
adapter a complete charge control function for charging of Li-Ion or Li-Ion-Polymer batteries. Either a
1-cell Li-Ion or Li-Ion-Polymer battery with 4.1, 4.2 or 4.4 Volts may be used.
1. Charging method : CC-CV
2. Charger detect voltage : 4.0 V
3. Charging time : 2h 40m
4. Charging current : 380 mA
5. CV voltage : 4.2 V
6. Cutoff current : 110 mA
7. Full charge indication current (icon stop current) : 110 mA
8. Recharge voltage : 4.16 V
9. Low battery alarm
a. Idle : 3.43 V ~ 3.3 V
b. Dedicated : 3.53 V ~ 3.3 V
10. Low battery alarm interval
a. Idle : 3 min
b. Dedicated : 1 min
11. Switch-off voltage : 3.3 V
12. Charging temperature adc range
a. ~ -5°C : low charging voltage operation (3.6 V ~ 3.9 V) .
b. -5°C ~ 50°C : standard charging (up to 4.2 V)
c. 50°C ~ : low charging voltage operation (3.6V ~ 3.9V)
- 36 -
3. TECHNICAL BRIEF
LGE Internal Use Only
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
3.69V~3.53V
3.53V~3.43V
3.43V~3.35V
Figure 5 Battery Block Indication
4.2V~3.69V
Содержание KP500
Страница 1: ...Service Manual Model KP500 Service Manual KP500 Date October 2008 Issue 1 0 Internal Use Only ...
Страница 119: ... 120 LGE Internal Use Only Copyright 2008 LG Electronics Inc All right reserved Only for training and service purposes ...
Страница 127: ... 128 LGE Internal Use Only Copyright 2008 LG Electronics Inc All right reserved Only for training and service purposes ...
Страница 147: ...LGE Internal Use Only Copyright 2008 LG Electronics Inc All right reserved Only for training and service purposes 148 ...
Страница 169: ...Note ...
Страница 170: ...Note ...