- 80 -
4. TROUBLE SHOOTING
LGE Internal Use Only
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
RTC will work properly
Is frequency
at R102 about 32.768KHz?
START
Resolder the X100 or
change the X100
NO
YES
YES
Is voltage
at R102 about 400mV?
Resolder the X100 or
change the X100
NO
Is RTC properly working?
NO
Re-download software and try
again
YES
CHECK FLOW